Solenoid Valves
Description
Symbol
Cross Section
Cavity Details
312
All external surfaces are zinc plated and corrosion-pro-
of. All valve parts are made of high strength steel. Pop-
pet is hardened and ground to ensure minimal wear and
extended service life. Coil seals protect the solenoid sy-
stem. Manual override options. Industry SAE common
cavity.
Solenoid operated, 2-way 2-positions, normally closed, pi-
loted poppet type, screw-in cartridge valve. Typically used
as a blocking or load holding device for high pressure cir-
cuits. When the coil is de-energized, the SVS0.S08 acts as
check valve allowing free flow from 1 to 2, while blocking
from 2 to 1. When the coil is energized the poppet lifts and
opens the 2 to 1 flow path. In this operation mode, flow
from 1 to 2 is severely restricted. The rigid design using a
1-piece body contributes to minimize the effect of eccen-
tricities in cavity and provides great reliability. Low pressu-
re drop thanks to optimized flow path.
SAE08
SVS0.S08 Valve Series
SAE Cartridge - 350 bar
NC Single Lock Pilot Operated
Poppet Type
Technical Features
Specications may change without notice.
313
Maximum operating pressure 350 bar
Maximum flow 40 l/min
Maximum internal leakage 0,25 cm
3
/ min @350 bar
External component treatment
Zn/Fe - standard (96h)
Zn/Ni (720h)
Switch ON Time 30 ms
Switch OFF Time 50 ms
O-ring Temperature Range -30° C to 110° C (standard sealing NBR - BUNA-N)
Oil Temperature Range -30° C to 110° C
Fluids Mineral - based or synthetics with lubricating properties
Viscosities 7,4 to 420 cSt
Minimum pull-in voltage 85% of nominal
Filtration 20/18/15 ISO 4406 (maximum ltration admitted)
Orientation No restrictions
Installation torque 40 - 45 Nm (Hex. 24)
Technical Specications for characterization see page 480
Oil testing condition ISO VG 46 cSt
Seal kit code SK.030 and SK.027 (coil)
Coil 18W (for more detalis see page 410-425)
Weight 0,110 kg
Performance Details
Technical Data
Ordering Code
Pressure (bar)
Flow (l/min)
Note: The performance chart
illustrates flow handling
capacity 2 to 1 (energized). p/Q
curve is recorded at TOil = 40°C
and 46 cSt.
NOTE: for more details see page 426-427.
Note: All Solenoid cartridge valves listed in the present catalogue
are designed to work with D.C. power supply. To work with A.C.
power supply, a RAC coil and connector with rectier must be
used. For any additional information, please contact your Sales
contact representative.